Electrical Data - ABB CEMcaptain GAA610-M Operating Instruction

Advanced emission gas monitoring system for marine applications
Table of Contents

Advertisement

GAA610-M ADVANCED EMISSION GAS MONITORING SYSTEM | OI/GAA610-M-EN REV. B

Electrical Data

Power supply
Terminals
Operating voltage
Frequency
External fuse
Power consumption
System cabinet
Air conditioner
Sampling probe
Heated sample gas line
Heated sample gas line
Terminals
Power supply output
Maximum output current
Maximum output power
Internal fuse protection
Sample gas probe & heated filter unit
Terminals
Power supply output
Maximum output current
Maximum output power
Internal fuse protection
-X60: L, N, PE or L1, L2, PE
230 V AC, ±10 %
50 / 60 Hz, ±3 Hz
Approx. 90 W/m
-X64 – 1, 2, PE
Power supply:
-X62 – 9, 10, 11
Three-Wire Pt100:
-X62 – 9, 10, Bridge
Two-Wire Pt100
between 10+11
RCD 16 A, 30 mA
-X60 – 3, 4, PE
Power supply:
-X62 – 5, 6
Probe heater alarm:
Backpurging unit
Terminals
Power supply output
Maximum output current
25 A
Internal fuse protection
500 w
1600 W
300 W
Current outputs
Terminals
Current output
Maximum load
Resolution
Design
230 V AC
12 A
2.7 kW
Digital inputs / outputs
Terminals
230 V AC
1.3 A
Digital outputs (DO)
300 W
6 A
Digital inputs (DI)
Valve 1:
Valve 2:
CO
, 0 to 20 %
2
SO
, 0 to 250 ppm:
2
SO
/CO
ratio, 0 to 250
2
2
Shield
Joint minus pin, electrically isolated, randomly
DO – System failure
DO – Maintenance
DO – Maintenance request
DO – Measuring range feedback SO
DI – Measuring range request
Shield
Potential-free contacts
(powerless status opened, fail safe),
Optoelectronic coupler
with internal power supply 24 V DC,
Control with floating contacts,
with external voltage 12 to 24 V DC
or with open collector drivers PNP or NPN
37
-X62 – 1, 2
-X62 – 3, 4
24 V DC
1 A
2 A slow blow
-X65 – 1+, 2−
-X65 – 3+, 4−
-X65 – 5+, 6−
-X65 – 7+, 8−
-X65 – S
4 to 20 mA
750 Ω
16 bit
groundable
-X63 – 1, 2
-X63 – 3, 4
-X63 – 5, 6
-X63 – 7, 8
2
-X63 – 9, 10
-X65 – S
max. 30 V DC,
max. current 1 A,

Advertisement

Table of Contents
loading

Table of Contents