GAA610-M ADVANCED EMISSION GAS MONITORING SYSTEM | OI/GAA610-M-EN REV. B
... 12 Diagnosis / Troubleshooting
... Possible status messages
No.
Text
116
The Profibus Module is mounted on the wrong
slot! The Profibus interface is therefore not
working. Please remount the Profibus Module on
slot X20/X21.
117
The configuration backup was saved.
118
The configuration backup was loaded. The
system has been restarted.
119
The system configuration could not be loaded!
This system therefore contains no configuration
now. Please enter menu: Configure/System/Save
Save configuration to load your backup
configuration. Or use SMT to re-install your
configuration.
System bus
201
The selected system bus module could not be
found.
203
The selected system bus module does not exist.
208
The system bus was not able to transfer data into
the database.
209
The system bus connection
to this module is interrupted.
210
The system bus module configuration has
changed.
211
The system bus module has no more on-board
memory.
214
The system is currently maintained with Optima
SMT.
215
The analyzer module has an internal
communication error!
216
The analyzer module has an internal program
error!
250
The selected analyzer module could not be found! x
251
The connection to the analyzer has been lost!
252
The EEPROM data of the analyzer is faulty!
253
Communication with the analyzer is faulty!
254
The boot program of the analyzer is defective!
Notify Service!
255
The program of the analyzer is defective! Notify
Service!
S
A
W
F
Reaction/Remark
x
x
See message text
x
x
See message text
x
x
Check plug connections and terminating resistors on the system bus. Make sure the
system bus module serial number is correctly entered:
'MENU / Diagnostic/Information / System overview'
x
x
Check plug connections and terminating resistors on the system bus.
x
x
The system bus module software version is not compatible with that of the system
controller; update the system controller software.
x
x
Check the system bus connection to the indicated system bus module. Check the
power supply system of the indicated system bus module.
x
x
For information; the configuration data are automatically updated
x
x
Check the system bus module configuration:
'MENU / Diagnostic/Information / System overview'
x
x
Notify Service.
x
x
Notify Service.
x
Check the connectors and cabling.
x
x
Check the connectors and cabling.
x
x
Check the configuration with TCT.
x
x
Check the connectors and cabling.
x
x
Notify Service.
x
x
Notify Service.

Advertisement

Table of Contents
loading

Table of Contents