ABB CEMcaptain GAA610-M Operating Instruction page 62

Advanced emission gas monitoring system for marine applications
Table of Contents

Advertisement

62
GAA610-M ADVANCED EMISSION GAS MONITORING SYSTEM | OI/GAA610-M-EN REV. B
... 12 Diagnosis / Troubleshooting
... Possible status messages
No.
Text
Uras
318
No new measured values from the analog/digital
converter.
Temperature regulator
324
Temperature is above or below upper and/or
lower limit value 1.
325
Temperature is above or below upper and/or
lower limit value 2.
Pressure regulator
326
No new measured values from the analog/digital
converter.
327
The measured value exceeds the range of the
analog/digital converter.
328
A calculation error occurred during calculation of
the measurement value.
I/O devices
332
Auxiliary voltage failure on I/O board.
333
Unavailable I/O type configured.
334
No new measured values from the analog/digital
converter.
335
The measured value exceeds the range of the
analog/digital converter.
336
A calculation error occurred during calculation of
the measurement value.
337
Broken analog output line
338
Line break in the digital input (moisture sensor).
339
Line break or short circuit in the analog input.
340
Analog input value exceeds upper or lower limit
value 1.
341
Analog input value exceeds upper or lower limit
value 2.
S
A
W
F
Reaction/Remark
x
x
Notify Service.
x
Status messages during the warm-up phase.
If the Status messages appear following the warm-up phase: Check whether the
permissible ambient temperature range (see Climatic Conditions on page 19) is being
x
maintained. Check the analyzer module thermal link and replace if necessary.
x
x
Notify Service.
x
x
Notify Service.
x
x
Notify Service.
x
x
Defective I/O board. Replace the board.
x
x
Correct the configuration with the test and calibration software.
x
x
Defective I/O board. Replace the board.
x
x
Check signals at analog inputs.
If OK, check the configuration and calibration of the analog inputs.
x
x
Check the configuration and calibration of the analog inputs and outputs.
x
x
Check the analog output lines.
x
x
Check moisture sensor in the system cooler.
x
x
Check system cooler temperature.
x
Check system cooler temperature.
x
Check system cooler temperature.