SWITCH
DEFAULT
S3-5
OFF
S3-6
ON
S3-7
OFF
S3-8
OFF
S4-1
OFF
S4-2
OFF
S4-3
OFF
S4-4
OFF
S4-5
OFF
S4-6
OFF
JUMPER
DEFAULT
J5
Open
(RESET)
J7
5-6 short
(1TX)
119
FUNCTION
Ban or permission of a
"ROT" sentence output
For Simrad use
Not used
Gyro running/remote
buzzer stop output
Not used
Not used
Not used
Alarm detection time
Enable/disable THS
Not used

Jumper settings on SCC boards

FUNCTION
CPU reset
Serial signal output
setting
DIP SWITCH SETTINGS
DESCRIPTION
Valid at the time of external sensor (standard)
selection.
OFF = Disabled
ON = Enabled
OFF =
Not used
ON =
Simrad GC type (80 or 85) shown in
display at start-up according to S1-2
setting.
-
OFF = Gyro running
ON = Remote buzzer stop
-
-
-
OFF = 300 ms
ON = 2 sec
OFF = HDT
ON = THS
-
DESCRIPTION
Used to reset the CPU
Output port: GTERM-A board, "1TX"
1-2 Short =
Not used.
3-4 Short =
IEC61162-2 ed.1 or
TOKIMEC version
5-6 Short =
IEC61162-1 ed.4
Ref. page 3.
NOTE:
Never use both
jumpers at the same
time!
988-12720-002