Remove the 4 screws securing the Sensitive element. Tilt the
Horizontal ring to the side where the plug is located, and carefully
remove the element from the compass.
5
Place the defective Sensitive element in its original packaging, and
put the rubber tube on top of the element.
6
Fasten the screw on the plug holder on the defective Sensitive
element.
7
Carefully lift the new element from its packaging, and remove the
rubber tube on top of the element.
The packaging and the rubber tube should be kept for re-use if the
Sensitive element has to be sent to factory for service!
8
Tilt the Horizontal ring to the side where the plug is located, and
carefully put the Sensitive element into the ring.
-
The socket on the Sensitive element should be located right
above the plug attached to the Horizontal ring.