Simrad GC80 Dual MK2 User Manual page 132

Hide thumbs Also See for GC80 Dual MK2:
Table of Contents

Advertisement

Simrad GC80/85 Dual MK2 Gyro Compass
SWITCH
DEFAULT
S1-7
OFF
S1-8
OFF
S2-1
OFF
S2-2
OFF
S2-3
ON
S2-4
OFF
S2-5
OFF
S2-6
ON
S2-7
OFF
S2-8
OFF
S3-1
OFF
S3-2
OFF
S3-3
ON
S3-4
OFF
988-12720-002
FUNCTION
Serial signal format
Alarm output setup
For debugging
(Do not touch)
Operating panel type
Pendulum ferry
Serial signal transmit
frequency IEC61162-1
ed.4
Not used
System select
information contact
Timer startup
Talker ID of "ROT"
sentence
Rate of turn scale
DESCRIPTION
OFF = IEC61162-2 ed.1 (NMEA0183, ref. page 3)
ON = Tokimec
OFF = All alarms
ON = Only power failures
-
OFF = GPANEL (NOT FOR BAM)
ON = GPANEL-A (FOR BAM)
OFF = Not connected/Buzzer stop enabled
ON = Pendulum function in use/Buzzer stop
disabled
SW2-5 OFF
= 1 sec (1 Hz)
SW2-6 OFF
SW2-5 OFF
= 100 msec (10 Hz)
SW2-6 ON
SW2-5 ON
= 200 msec (5 Hz)
SW2-6 OFF
SW2-5 ON
= Invalid
SW2-6 ON
-
OFF = No
ON = Yes
OFF = No
ON = Yes
OFF = "HE"
ON = "TI"
SW3-3 OFF
Max 30.0°/min.
SW3-4 OFF
SW3-3 OFF
Max 300.0°/min.
SW3-4 ON
SW3-3 ON
Max 120.0°/min.
SW3-4 OFF
SW3-3 ON
SW3-4 ON
Invalid
118

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gc85 dual mk2Gc80/85

Table of Contents