Ground wire
connection
33
9
Position the Sensitive element on the Horizontal ring by putting the
assembly jigs into the holes as indicated in the figure below.
Observe the rings on the jigs to ensure proper positioning. Insert
and fasten the 2 screws in the other holes.
ASSEMBLY JIG
WITH 2 CIRCLES
10
Replace the assembly jigs with the 2 remaining screws after placing
the ground wire as shown in the figure.
11
Loosen the screw on the plug-holder on the Sensitive element and
lift the holder 2-3 mm upwards.
12
Connect the plug to the connectors on the Sensitive element's PCB
according to the labelling on the PCB and on the wires. Make sure
that the pin guides on the plug are properly entered, and that the
wires are not twisted.
13
Firmly tighten the screw on the holder.
MAINTENANCE
ASSEMBLY JIG
WITH 1 CIRCLE
Pin guides
988-12720-002