Activating an external heading sensor

If an external heading sensor is connected to the GC80/85 system, the
following switches have to be set to enable the external heading sensor:
-
DIP switch no.5 on S1 on both SCC boards.
-
DIP switch no.1 (and 2) on S1 on the SCOIF board.
-
DIP switch no.3 (and 4) on S1 on the PCC board (on the back side of
the Dual MK2 control panel).
For a complete list of DIP switch settings, refer to DIP SWITCH SETTINGS,
page 113.
SCC boards
For location of the boards, refer the figure on the previous page.