Simrad GC80/85 Dual MK2 Gyro Compass
988-12720-002
HDT/THS
Selecting HDT/THS heading output data from the Gyro
The serial data output can be set as HDT or THS using DIP switch no.5 on
S4 on both of the SCC boards.
THS is disabled = HDT output
To output HDT and THS at the same time, S2-5 and S4-5 must both be set
to ON and S2-6 must be set to OFF. When outputting both at the same
time, the only available output frequency is 1 Hz.
Selection of PTKM and ROT output
It is possible to set the sentences PTKM and ROT to output at the same
time as the heading data.
To do so, use the extension menu A-2:
2.G.P
PTKM sentence output
2.H.r
ROT sentence output
THS is enabled = THS output
bE = ON/send
Non = OFF/not send
bE = ON/send
Non = OFF/not send
54