JUMPER
DEFAULT
J42
3-4 short
(MALCN)
J43
1-2 short
(MRNCN)
J44
3-4 short
(DFCN)
J45
3-4 short
(OCACN)
127
FUNCTION
Alarm contact output for
Control panel
(or Change Over panel)
Running contact output
for Control panel
(or Change Over panel)
Difference alarm contact
output for Control panel
(or Change Over panel)
Off course alarm contact
output
(Not used)
DIP SWITCH SETTINGS
DESCRIPTION
Output port: DTERM-A board. TB21D:
" MALCN"
1-2 short =
Normal "CLOSES"
Alarm "OPEN"
3-4 short =
Normal "OPEN" Alarm
"CLOSES"
NOTE:
Never use both
jumpers at the same
time!
Output port: DTERM-A board. TB21D:
" MRNCN"
1-2 short =
Running "CLOSES" Stop
"OPEN"
3-4 short =
Running "OPEN" Stop
"CLOSES"
NOTE:
Never use both
jumpers at the same
time!
Output port: DTERM-A board. TB21D:
"DFCN"
1-2 short =
Normal "CLOSES"
Alarm "OPEN"
3-4 short =
Normal "OPEN" Alarm
"CLOSES"
NOTE:
Never use both
jumpers at the same
time!
Output port: DTERM-A board. TB21D:
"OCACN"
1-2 short =
Normal "CLOSES"
Alarm "OPEN"
3-4 short =
Normal "OPEN" Alarm
"CLOSES"
NOTE:
Never use both
jumpers at the same
time!