Download Print this page

Housing (3.2.1) - Epson RS-353 Service Manual

Advertisement

3.2.1 Removing the Lamp inner housing
Prerequisite conditions: None,
Lamp cover
Screw
Screw.
Lamp
housing
ner
1. Remove the lamp cover mounting screws from the main unit bottom plate and
remove the lamp cover.
Screw:
P/N1021771 (mounting torque: 4.5 kg.cm = 3.9
2. Remove two lamp inner housing mounting screws.
Screw:
P/N1021771 (mounting torque: 4.5 kg.cm = 3.9 Ib.inch)
3. Pull up the handle on the lamp inner housing and remove the lamp unit.
Warning:
1) The lamp unit is very hot immediately after it is in use and may cause burns if you
handle it carelessly.
Before removing the lamp unit, make sure the temperature of
the lamp inner housing unit has cooled down.
2) When installing the lamp unit, take care not to touch the lamp's reflector with a hand
(to prevent the reflector from being contaminated).