Setting The Origin; Installing The Teaching Pendant (T/B) - Mitsubishi RH-3SQHR3515 Instruction Manual

Table of Contents

Advertisement

2Unpacking to Installation

2.4 Setting the origin

The origin is set so that the robot can be used with a high accuracy. After purchasing the robot, always carry out
this step before starting work. This step must also be carried out if the combination of robot and controller being
used is changed.
There are several methods for setting the origin, but the origin data input method will be explained here. Refer to
Page 80, "5.6 Resetting the origin"
The teaching pendant is required for this operation.
[Caution] If the origin data at shipment is erased due to out of battery, it is necessary to set the origin again.
Refer to

2.4.1 Installing the teaching pendant (T/B)

When installing and removing the T/B, turn off the controller power supply. If T/B is installed or removed in the
state of power supply ON, emergency stop alarm will occur.
If you use the robot wherein T/B is removed, please install the attached dummy connector. With the connector,
put the dummy connector or draw it out.
CAUTION
Explain the installation method of T/B below.
1) Check that the POWER (power supply) switch of the robot controller is OFF.
2) Connects T/B connector to the robot controller. Use as the upper surface the lock lever shown in
and push in until there is sound.
A部
Dummy connector
Fig.2-9 : Installing and removing the T/B
The installation of T/B is finished.
◇◆◇ If error C0150 occurs ◇◆◇
At the time of the first power supply injection, error:C0150 (the serial number of the robot arm has not been
set up) occur the robot after purchase.
Parameter: Please input the serial number of the robot body into RBSERIAL. Refer to "instructions manual /
controller setup, and basic operation & maintenance" for the operation method.
Setting the origin
2-18
for the other methods.
Page 80, "5.6 Resetting the origin"
Please do not pull the cable of T/B strongly or do not bend it too much.
It becomes the breaking of a wire of the cable and the cause of breakage of the
connector. Please installing and removing so that stress does not start the cable
with the connector itself.
T/B connector
and reset the origin using the jig method or ABS method.
Details of the A section
B
When removing the connector for T/B connection,
use lock release (state which raised the lock lever
to the up side), make the case of the B section
slide to the front, and remove and pull up out the latch.
Teaching pendant
(T/B)
Fig.
Lock lever
2-9,

Advertisement

Table of Contents
loading

Table of Contents