OPERATION
4.
After refuelling is complete:
(a) Push float gauge (G) straight down with fuel filler cap
(F), be careful not to get the float gauge (G) caught in the
tab of the fuel filler cap (F) and tighten fuel filler cap (F) se-
curely.
(b) Tighten strainer valve cap (H) to the closed position (K)
to prevent leakage of fuel left in the hose.
(c) Replace the fuel hose in the tool case (3).
METHOD FOR DRAINING WATER AND SEDIMENT FROM FUEL TANK
1.
Prepare a container under drain hose (1) to receive fuel.
2.
Turn drain valve (2) to OPEN position (O) to drain all the
sediment and water accumulated at the bottom together
with fuel.
3.
When only the clean fuel flows out, turn drain valve (2) to
CLOSE position (S).
METHOD FOR CHECKING WATER SEPARATOR, DRAINING WATER AND SEDI-
MENT
1.
Open the door on the right side of the machine.
2.
Check for water and sediment.
It is possible to judge the water level and amount of sedi-
ment by looking through transparent cup (2).
NOTICE
If the water inside transparent cup (2) freezes, check
that the frozen water has melted completely, then fol-
low the procedure to drain the water.
3.
Put a container to receive the water under drain hose (3).
4.
Loosen drain valve (4) and drain the water.
MACHINE OPERATIONS AND CONTROLS