2.
Select the set time on the "Auto Idle Stop Timer Setting"
screen shown in the figure, and then press switch F6.
On the "Auto Idle Stop Timer Setting" screen shown in the
figure, you can perform the following operations with
switches F3 to F6.
F3: Moves to the next item (1 line below). When on the last
line, it moves to the first line.
F4: Moves to the previous item (1 line above). When on
the first line, it moves to the last line.
F5: Cancels the selection and returns the screen to the
"Machine Setting" menu screen.
F6: Allocates the selected setting to that of the Auto Idle Stop Timer Setting.
REMARK
Choosing "OFF" disables operation of the auto idle stop function.
You cannot select a time longer than that specified in the Service Menu.
3.
When the idling time reaches 30 seconds before the set
time, the monitor returns to the standard screen and
changes to the countdown screen.
If you set the lock lever to FREE position, countdown stops
and the screen returns to the standard screen.
4.
When countdown reaches 0, the engine stops and the
screen changes to the "Auto Idle Stop in Operation"
screen.
5.
To prevent battery discharging, turn off unnecessary
switches.
REMARK
While the auto idle stop is activated, only the engine is
stopped and the machine monitor, inverter, etc., as well as
the electrical components including the air conditioner, ra-
dio, lamps, and wipers keep their states before the engine
is stopped.
6.
To prevent battery discharging, turn the starting switch to OFF position.
7.
When restarting the engine, turn the starting switch as usual.