Levelflex M FMP40 with HART/4...20 mA
Endress+Hauser
3.6.9
Turning the housing
After mounting, you can turn the housing 350° in order make it easier to access the display and the
connection compartment. Proceed as follows to turn the housing to the required position:
• Undo the fixing screw (1)
• Turn the housing (2) in the required direction
• Tighten the fixing screw (1).
F12/F23 housing
2
1
3.7
Post-installation check
After the measuring device has been installed, perform the following checks:
• Is the measuring device damaged (visual inspection)?
• Does the device correspond to specifications at the measuring point, including process
temperature and pressure, ambient temperature, measuring range, etc.?
• Are the measuring point number and labeling correct (visual inspection)?
• Is the measuring device adequately protected against rain and direct sunlight (see → ä 62)?
T12 housing
2
1
allen key
4 mm/0.1"
Installation
L00-FMP4xxxx-17-00-00-en-028
27