Appendix; Hart Operating Menu (Display Module) - Endress+Hauser Levelflex M FMP40 Operating Instructions Manual

Run time measurement
Hide thumbs Also See for Levelflex M FMP40:
Table of Contents

Advertisement

Appendix

basic setup
00
tank properties
partially filled
fully flooded
safety settings
01
output on alarm
MIN -10% 3.6mA
MAX 110% 22mA
hold
user specific
length adjustment
03
probe
covered
free
linearisation
04
level/ullage.
level CU
ullage CU
level DU
ullage DU
extended calibr.
05
Selection
mapping
common
delete map.
output
06
PV Select
interface
level
upper phase
envelope curve
0E
plot settings
envelope curve
substracted signal
mapping
display
09
language
English
Deutsch
Francais
Espanol
Italiano
Nederlands
Katakana (japanese)
diagnostics
0A
present error
system parameter
0C
tag no.
Note! The default values of the parameters are typed in boldface.
82
11
Appendix
11.1

HART operating menu (display module)

002
process proper.
004
empty calibr.
enter value
standard
fast change
slow change
test: no filter
010
outp. echo loss
alarm
hold
output on alarm
011
enter value
032
probe length
033
determine length
length OK
probe length
033
too short
too long
040
linearisation
041
customer unit
customer unit
linear
horizontal cyl
customer unit
manual
table on
clear table
050
range of mapping
input of mapping
range
035
SV Selcet
036
TV Select
interface
interface
level
level
upper phase
upper phase
ampl. level
0E1
recording curve
0E2
single curve
cyclic
format display
092
back to home
093
enter time
decimal
Default: 900 s
1/16"
0A0
previous error
0A1
clear last error
0C0
protocol + sw-no.
Levelflex M FMP40 with HART/4...20 mA
005
full calibr.
006
upper block.dist
enter value
0.1
012
delay time
014
safety distance
in case of echo loss
from blocking distance
034
042
042
042
linearisation
next point
no
043
TabNo
044
Level
045
Volum
yes
052
start mapping
053
dist./meas.value
no
Level and Interface
yes
are displayed
pres. Map dist.
054
delete map.
is displayed
no
yes
037
PV and SV
038
TV and QV
commun.address
060
no. of preambels
094
no.of decimals
095
sep. character
x
. point
x.x
, comma
x.xx
x.xxx
0A2
reset
0A3
unlock parameter
for reset code
for enter code
see manual
see manual
0C2
serial no.
059
medium cond.
003
2
015
in safety dist.
016
alarm
warning
self holding
045
008
Installation
007
byp./pipe/coax
051
free in tank
039
061
low output limit
062
off
on
096
display layout
098
PV + SV
PV + SV altern
PV only
0A4
measured dist.
0A5
0C4
distance unit
0C5
L00-FMP4xIxx-19-00-01-en-003