Levelflex M FMP40 with HART/4...20 mA
Mounting with threaded boss
F12/F23 or T12 housing
F12/F23 or T12 housing
Endress+Hauser
3

Installation

3.1

Quick installation guide

1½"
Caution!
Use only the
threaded boss
AF 60
1.
¾"
AF 50
2.
1.
When using an aramid fibre seal and a process pressure of 40 bar: 140 Nm
Maximum permissible torque: 450 Nm
2.
When using an aramid fibre seal and a process pressure of 40 bar: 25 Nm
Maximum permissible torque: 45 Nm
The housing can be turned 350°
in order to simplify access to the
display and the terminal compartment
F12/F23 housing
2
3
1
T12 housing
2
3
1
Allen key
4 mm / 0.1"
Installation
L00-FMP4xxxx-17-00-00-en-029