Endress+Hauser Levelflex M FMP40 Operating Instructions Manual page 22

Run time measurement
Hide thumbs Also See for Levelflex M FMP40:
Table of Contents

Advertisement

Installation
!
22
3.6.5
Replacing a displacement system in an existing displacer
chamber
The Levelflex M is a perfect replacement for a conventional displacer system in an existing displacer
chamber. In addition to the DIN and ANSI flanges, which are available as standard,
Endress+Hauser also offers flanges that suit Fischer and Masoneilan displacer chamber (special
product) for this purpose. Thanks to menu-guided local operation, commissioning the Levelflex M
only takes a few minutes. Replacement is also possible when partially filled, and wet calibration is
not required.
Your benefits:
• No moving parts, thus zero-maintenance operation.
• Not sensitive to process influences such as temperature, density, turbulence and vibrations.
• The rod probes can be shortened or replaced easily. In this way, the probe can be easily adjusted
on site.
Planning instructions:
• In normal cases, use a rod probe. When installing into a metal displacement housing up to
150 mm (100 mm for interface), you have all the advantages of a coax probe.
• It must be ensured that the probe does not come into contact with the side wall. Where necessary,
use a centering disk at the lower end of the probe (→ ä 8 "Type of Probe:").
• A centering disk must be adapted as accurately as possible to the internal diameter of the displacer
chamber to also ensure perfect operation in the area of the probe end.
Additional information on interface measurement
• The pipe may not exhibit any steps in diameter. Use the coax probe where necessary.
• In the case of rod probes, it must be ensured that the probe does not come into contact with the
wall. If necessary, use a centering disk at the end of the probe.
Note!
A plastic centering disk has to be used for interface measurement, see Accessories → ä 64.
Levelflex M FMP40 with HART/4...20 mA
displacer chamber flange
L00-FMP4xIxx-17-00-00-en-002
Endress+Hauser

Advertisement

Table of Contents
loading