Installing the unit

6. Installing the unit
Before installing the unit, the packaging must be removed, taking special care not to damage the housing.
Check that there is no condensation inside the packaging. If there are signs of condensation, the unit must not be
installed until you are sure it is completely dry.
CAUTION
All installation operations must comply with current regulations.
All operations involving moving heavy weights must be carried out by two people.

6.1. General requirements for installation

The environment of the unit must be appropriate and meet the guidelines described in chapter "5.
Preparation for installing the unit". Additionally, the parts used in the rest of the installation must be
compatible with the unit and comply with the applicable legislation.
The ventilation and workspace must be suitable for maintenance tasks according to the applicable
regulations in force.
The external connection devices, which must be suitable and sufficiently close as set forth in current
regulations.
The feed cables must be of the appropriate gage for the maximum current.
Special care must be taken to ensure that there are no external elements near the air inlets and outlets
that obstruct proper cooling of the unit.

6.2. Attaching the unit to the wall

INGECON SUN STORAGE 1Play units have a system for securing them to the wall using a plate. The steps for
fixing the unit properly are as follows. The weight of the unit must be taken into account.
1.
Mark the fixing points for the plates on the wall and drill holes with a suitable bit for the screws to be
used to secure the plate to the wall later.