TP Cable Termination and Recommendations

The TIA/EIA T 568B wiring standard is detailed in figure 6. Use this standard to terminate
TP cables with RJ‑45 connectors.
Side
Figure 6.
ATTENTION:
Do not use Extron UTP23SF‑4 Enhanced Skew‑Free AV UTP cable or STP201
cable to link the XTP products or with DTP2 transmitters or receivers. The
DTP2 211 does not work properly with these cables.
N'utilisez pas le câble audiovisuel Skew‑Free UTP version améliorée UTP23SF‑4
Extron ou le câble STP201 pour relier les produits XTP à des émetteurs ou
récepteurs DTP2. Le DTP2 211 ne fonctionne pas correctement avec ces câbles.
Supported cables —
The DTP2 211 transmitter and receiver are compatible with CAT 6a, and  CAT 7 shielded
twisted pair (F/UTP, SF/UTP, and S/FTP) and unshielded twisted pair (U/UTP) cable.
Cable recommendations —
Extron recommends using the following practices to achieve full transmission distances up
to 330 feet (100 meters) and reduce transmission errors.
Use the following Extron XTP DTP 24 SF/UTP cables and DTP 24 connectors for the
best performance:
XTP DTP 24/1000
XTP DTP 24P/1000 Plenum 1000 feet (305 meters) spool
XTP DTP 24 Plug
If not using XTP DTP 24 cable, at a minimum, Extron recommends 24 AWG, solid
conductor, STP cable with a minimum bandwidth of 400 MHz.
Terminate cables with shielded connectors to the TIA/EIA T 568 B standard.
Use no more than two pass‑through points, which may include patch points, punch
down connectors, couplers, and power injectors. If these pass‑through points are
required, use CAT 6 or 6a shielded couplers and punch down connectors.
NOTES: When using CAT 6a and CAT 7 cable in bundles or conduits, consider the following:
Do not exceed 40% fill capacity in conduits.
Do not comb the cable for the first 65 feet (20 meters), where cables are
straightened, aligned, and secured in tight bundles.
Loosely place cables and limit the use of tie wraps or hook‑and‑loop fasteners.
Separate twisted pair cables from AC power cables.
Pins:
RJ-45
1 2 3 4 5 6 7 8
Connector
TIA/EIA T
568 B
Pin
Wire color
1
White-orange
Orange
2
3
White-green
4
Blue
5
White-blue
6
Green
Insert
7
White-brown
Twisted
8
Brown
Pair Wires
TP Cable Termination
Non‑Plenum 1000 feet (305 meters) spool
Package of 10
DTP2 T/R 211 • Installation and Operation