Internal Settings

ATTENTION:
There are two internal jumpers used to configure the DTP2 ground lift and remote power.
The jumpers have the following numbering scheme and function:
Ground Lift:
48 VDC Remote
Power:
NOTES:
Use electrostatic discharge (ESD) precautions (be electrically grounded) when
making connections.
Prenez des précautions contre les décharges électrostatiques (soyez
électriquement relié à la terre) lorsque vous effectuez des connexions.
Avoid ground potential differences between the transmitter and receiver
installation sites, which can lead to equipment damage or a missing or
unstable picture. If a potential difference cannot be avoided, remove the ground
connection between the units and locally power both units.
Évitez les différences de potentiel de mise à la terre entre les sites d'installation
d'émetteur et de récepteur de commutation, qui pourraient endommager
l'équipement ou rendre l'image invisible ou irrégulière. Si une différence de
potentiel ne peut être évitée, enlevez la connexion de mise à la terre entre les
unités et alimentez les deux unités localement.
Jumper
Function
Closed —
Ground is not
Rx — J2
lifted (default)
Tx — J9
Open —
Ground is lifted.
On — Remote
power is
distributed
Rx — J3
(default).
Tx — J12
Off — Remote
power is
disabled.
If the ground jumper is open, a DTP2 211 unit cannot remotely power the other
unit, because of ground potential differences. Each unit requires a local power
supply.
If the 48 VDC remote power jumper is off, DTP2 211 unit cannot remotely power
the other unit. Each unit requires a local power supply.
Jumper
Pins 1 and 2
Pins 2 and 3
1
Closed
Open
3
1
On
Off
3
DTP2 T/R 211 • Reference Information