Safety Instructions - VETRON 5300 Instruction Book

Table of Contents

Advertisement

General Safety Instructions
This manual and the warning symbols on the machine should en-
sure the safe use of the machine, so that no accidents and injuries
may occur to you and others. Please read this instruction and also
the safety instructions of the motor manufacturer carefully.
» The machine must only be operated in accordance with its
intended purpose (for example, sewing medium to heavy ma-
terials such as jeans, leather, etc. NO tin!) and with the as-
sociated protective equipment. The relevant country-specific
safety regulations and technical data must also be observed.
» The machine should only be used in accordance with its inten-
ded purpose (eg sewing medium to heavy materials such as
jeans, leather, etc.) and with the associated protective equip-
ment. The relevant country-specific safety regulations and
the technical data must also be observed.
» The machine should only be set up and operated in dry and
well-kept rooms.
» Do not place the machines outdoors, next to radiators or heat
source. The ambient temperature should not be lower or hig-
her than between 0° C to 45° C.
» The machine must only be commissioned after the relevant
operating instructions have been taken into consideration and
by appropriately instructed operators.
» These instructions are to be stored at hand.
» The connection cable must be provided with a country-
specific approved mains plug. The mains plug must only be
connected to grounded sockets. Here a qualified specialist is
necessary.
» The machine must always have a grounding. Only over this is
a normal operation of the machine to ensure.
» The danger and safety instructions attached to the machine
must be followed.
» When replacing sewing tools such as needle, sewing
foot, stitch plate, feed dog or bobbin, when threading,
when leaving the workplace and during maintenance,
etc., the machine must be disconnected from the mains.
 Press the main switch or pull out the mains plug.
» Machines with compressed air components must be discon-
nected from the compressed air supply and the residual pres-
sure released before repair or maintenance work. Exceptions
to this are performance tests or specific settings.
» Repairs and all maintenance work should only be carried out
by qualified personnel or appropriately instructed persons.
» Work on electrical equipment must only be carried out by
qualified specialists.
 If errors are detected, stop the machine immediately.
» Work on parts and equipment that are live is not permitted.
The machine must be disconnected from the mains.
» Modifications or modifications to the machine must be carried
out in compliance with all relevant safety regulations. The
manufacturer assumes no responsibility for damage caused
by changes or modifications.
» For repairs, only spare parts approved by VETRON may be
used. In case of infringement the guarantee expires.
» The machines are to be used only for the purpose intended.
» If oils, greases, etc., used for the machines and accessories,
get in your eyes or on your skin, or should you swallow any of
these fluids, wash them immediately and thoroughly, or seek
medical attention immediately.
» Commissioning of the machine is prohibited until it has been
determined that the entire sewing unit complies with the pro-
visions of the EC directive and the declaration of conformity
has been created.
Advice to the Owner
» As part of the machine, this operating manual must be availab-
le to operating personnel at all times. Before using the machine
for the first time, the operator must read this operating manual.
» The operator has to ensure that the machine is only operated
in perfect condition.
» The operator must ensure that no safety devices are removed
or disabled.
» The operator must ensure that only authorized or properly in-
structed persons work on the machine.
» The operator must therefore ensure that the workstations ac-
cording to ASR lux. 4 are adequately illuminated (min. 750 lux).
Operators and Technical Sta
» The operating personnel are responsible for setting up, ope-
rating and cleaning the machine and responsible for the eli-
mination of faults.
» Qualified personnel include people with specialist trai-
ning in electrical / electronics, pneumatics and mechanics.
 Lubrication, maintenance, repair and adjustment are your
responsibilities.
» The operator must refrain from any operation that impaires
the safety on the machine.
1. Jewelry, chains and rings - must not be worn.
2. The clothes should be tight
3. Only authorized persons may enter the danger area.
» If changes occur to the machine that a ect safety, they must
be reported immediately to the operator.
» The specialist personnel - persons with training in electrical /
electronics and mechanics - are responsible for the lubrica-
tion, maintenance, repair and adjustment of the machine.
» Before starting adjustment and repair work, the main switch
must be switched o and secured against reclosing.
» Work on parts that are under tension should be avoided. Ex-
ceptions are regulated by EN 50110. After maintenance and
repair work, the protective covers must be replaced.
» Operating and specialist personnel are obliged to observe the sa-
fety instructions given in the instructions for use during all work.
VETRON 5300 - POST BED MACHINE - INSTRUCTION BOOK
01. PREFACE

01. SAFETY INSTRUCTIONS

07/2020
05

Advertisement

Table of Contents
loading

This manual is also suitable for:

53205380

Table of Contents