2.5.2 Wiring Examples - Siemens SIMATIC NET RUGGEDCOM RSG907R Installation Manual

Rugged
Hide thumbs Also See for SIMATIC NET RUGGEDCOM RSG907R:
Table of Contents

Advertisement

4.
5.
2.5.2
Wiring Examples
The following illustrate how to connect single and dual power supplies to the device.
RUGGEDCOM RSG907R
Installation Manual, 02/2020, C79000-G8976-1387-09
c.
Connect the ground wire to the
chassis/ground terminal on the
terminal block.
Connect the chassis ground screw to ground (Potential Earth). It is recommend-
ed to terminate the ground connection with an M4 ring or spade lug, and then
torque to 1.7 N·m (15 lbf-in).
M4 Screw
1
M4 Ring Lug
2
Figure 2.10
Chassis Ground Connection
Connect the power cable to the power source.
1
2
Installing the Device
2.5.2 Wiring Examples