Using a #6 ring lug and #6-32 screw, secure the ground terminal on the power
source to the chassis ground terminal on the device. Make sure the lug is tight-
ened to 1.7 N·m (15 lbf·in).
Figure 2.5
8.
Install the terminal block cover.
2.5.2
Wiring Examples
The following illustrate how to connect power to single and dual power supplies.
RUGGEDCOM M2100F
Installation Manual, 01/2020, C79000-G8976-1342-06
All manuals and user guides at all-guides.com
1
Stainless Steel Stud
1
#6-32 Screw
2
#6 Ring Lug
3
Chassis Ground Connection
DANGER
Electrocution hazard – risk of death, serious personal injury and/or damage
to the device
Make sure the supplied terminal block cover is always installed before the de-
vice is powered.
2
3
Installing the Device
2.5.2 Wiring Examples
15