4.
5.
2.5.2
Wiring Examples
The following illustrate how to connect single and dual power supplies to the device.
RUGGEDCOM RSG908C
Equipment Manual, 11/2023, C79000-G8976-1404-15
3.
Connect the ground wire to the
chassis/ground terminal on the
terminal block.
Connect the chassis ground screw to ground (Potential Earth). It is
recommended to terminate the ground connection with an M4 ring tongue, and
then torque to 1.7 N·m (15 lbf-in).
M4 Screw
1
M4 Ring Tongue
2
Figure 2.9
Chassis Ground Connection
Connect the external power supply to a power source. The Power LED on the
device will turn green when power is being supplied to the device.
1
2
Installing the Device
2.5.2 Wiring Examples