4. Lamp & Lamp House
Anode adapters and adaptation bushing
R859986K
Image 4-4
Cathode adapters for manual Lamp House
R8436101K
Image 4-5
The shortest cathode adapter R8436101K is no longer needed for xenon lamps supported by Barco. For that this adapter has
become obsolete.
4.3
Removal of the Lamp House
W
ARNING
W
ARNING
least 15 minutes before proceeding to remove the Lamp House.
C
AUTION
handled.
Necessary tools
10mm nut driver or flat screw driver.
How to remove the Lamp House from the projector?
1. Make sure the projector is switched off and cooled down.
2. Remove the cover of the Lamp House compartment.
3. Release the two retaining screws (reference 1 image 4-6) at the base of the Lamp House. Use a 10mm nut driver or a flat screw
driver.
4. Remove the Lamp House as follows:
28
R859985K
R859987K
R8436081K
R859984K
:
This procedure may only be performed by qualified technical service personnel.
:
The Lamp House is very hot after operation. To avoid burns, let the projector cool down for at
:
Due to its high internal pressure, the lamp may explode in either hot or cold states if improperly
R864132K
R8436111K
R8436061K
R59770491 DPXK-32B 17/09/2012