4. Lamp & Lamp House
Image 4-1
Left: Xenon lamp wrapped in a protective cloth. Right: Xenon lamp captured in a protective container.
C
AUTION
of the bulb increases the pressure to a level at which the bulb may explode if not handled in strict accordance
to the manufacturer's instructions. The bulb is stable at room temperature, but may still explode if dropped or
otherwise mishandled. Whenever the lamp house, containing a xenon lamp, has to be dismantled or whenever
the protective container or cloth has to be removed from the xenon lamp, authorized protective clothing MUST
be worn!
Lamp strike policy and lamp warning/error policy versus the lamp runtime
The projector issues a lamp run time notification message (end have blue status LEDs) approximately 30 hours before the
maximum lamp runtime occurs.
The projector issues a lamp run time notification message (end have blue status LEDs) when the maximum lamp runtime
occurs.
The projector will always try to strike the lamp, independent of the lamp runtime.
Parts identification xenon lamp
1
2
Image 4-2
1
Cathode of the xenon lamp.
2
Envelope (bulb) of the xenon lamp.
3
Anode of the xenon lamp.
4
Anode wire of the xenon lamp.
Parts identification manual Lamp House
1
2
3
Image 4-3
1
Air inlet cathode cooling.
2
Adjustment screw horizontal lamp alignment.
3
Positioning pin.
4
Connection Lamp Info module.
5
Positioning pin.
6
UV blocker.
26
:
Xenon compact arc lamps are highly pressurized. When ignited, the normal operating temperature
3
4
10
4
5
6
9
8
11
7
12
13