11.6 Cooling liquid refill
W
ARNING
Order info cooling liquid
B1909086K : bottle of 1 liter cooling liquid.
Necessary parts
Cooling liquid
How to refill
1. Remove the side cover, see "Removal of the side cover", page 86.
2. Open the filler cap by turning it anti clockwise.
Max
Min
Image 11-6
Cooling liquid refill
3. Fill the reservoir with cooling liquid until the level is equal with the Max indication on the reservoir.
4. Close the reservoir again. Turn the filler cap clockwise to close the reservoir.
5. Reinstall the side cover.
C
AUTION

11.7 Authorization to clear security warning on the projector

When is an authorization required to clear the security warning?
If a module has been removed or if the sealed compartment has been opened, an authorization will be required to clear the security
warning.
Necessary tools
Security key (Dallas iButton®).
Authorization pin code.
Authorization procedure to clear security warning
1. Ensure that all modules are properly installed.
2. Start up the projector (standby mode).
3. Initiate authorization by holding the security key in the security socket D..
R59770491 DPXK-32B 17/09/2012
:
This procedure may only be performed by qualified technical service personnel.
: