Power Requirements; Operating Rate; Operating Conditions; Tape - 3M 40800 Instructions And Parts List

Random case sealer with accuglide 3 taping heads
Hide thumbs Also See for 40800:
Table of Contents

Advertisement

4-SPECIFICATIONS

1. Power Requirements

Electrical: 115 VAC, 60 Hz, 6.4 A (675 watts)
Pneumatic: 85 PSIG [6 bar pressure], 2.5 SCFM
[70 liter/minute @ 2PC, 1.01 bar] maximum at maximum random cycle rate.
A pressure regulator/fi lter is included
The machine is equipped with a 2.4m [8 foot] standard neoprene covered power cord and a grounded plug.
Contact your 3M Representative for power requirements not listed above.

2. Operating Rate

Box drive belt speed is approximately 0.5 m/s [100 feet per minute].
45
40
35
30
25
20
15
10
5
0
IMPORTANT SAFEGUARD

3. Operating Conditions

Use in dry, relatively clean environments at 4.4
Note: Machine should not be washed or subjected to conditions causing moisture condensation on
components.

4. Tape

®
Scotch
pressure-sensitive fi lm box sealing tapes.

5. Tape Width

50mm [2 inches] minimum to 72mm [3 inches] maximum
0
5
10
To reduce the risk associated with fi re
and explosion hazards:
Do not operate this equipment in poten-
tially fl ammable or explosive environments.
15
20
25
o
o
o
C to 48.9
C [40
F to 120
WARNING
14
30
35
40
o
F] with clean, dry boxes.