4 - Specifi cations

4.1. Power Requirements:

Electrical: 120 VAC, 60 Hz, 6 A
Pneumatic: 5 bar gauge pressure [70PSIG]
110 liter/min @ 21°C, 1.01 bar [3.75 SCFM] at 15 boxes per minute
A pressure regulator is included

4.2. Operating Rate:

B
O
X
E
S
P
E
R
M
Actual production rate is dependent on the type of
I
infeed conveyor used and upstream line conditions
N
U
T
E
* Approximate, dependent on infeed conditions.
Machine is shipped with both cams (A and B) installed. To obtain production rate shown with
Note:
dotted line (cam A only), cam B must be removed. See "Adjustments – Gate Operation".
800af-I-NA
800af Box Rate vs. Box Length
- - cam A only ___ both cam A and B
610mm [24 in.] Box Spacing*
Box Length - Inches [Millimeters]
485mm [19 in.] Box Spacing*
13
(continued)