7-INSTALLATION AND SET-UP (continued)
WARNING
To reduce the risk associated with
impact hazards:
− Always use appropriate supporting
means when working under the upper
drive assembly
To reduce the risk associated with
mechanical and electrical hazards:
− Allow only properly trained and
qualifi ed personnel to operate and/or
service this equipment
7.11 Bumper Supports (Upper Drive Assembly)
With the Safety Guard removed (Figure 7-12):
Also See Special Set-Up Procedure -
Column Bumper Installation
Raise and lock the upper drive assembly in the
raised position. See "Operation – Mechanical
Latch."
Turn off air supply and electric power.
Remove the Column Bumper and set screw
parts package from the carton.
Using set screws provided, install Column
Bumper (the recommended position is
shown below).
Re-install Safety Guard.
* NOTE - IMPORTANT: - Some bumper positions may:
1) Allow upper and lower taping heads to come into
contact with each other.
2) Create added stress to the bumper.
3) Cause a malfunction of the machine.
These events can potentially cause damage to the machine.
For more information on bumper settings, contact
your 3M service representative.
700rks
(Shown is
after Safety
Guard is
Removed)
Figure 7-12
7.12 Box Size Capacity of Case Sealer
At its factory setting, the case sealer handles a
variety of box sizes. If larger capacity is
needed, the machine can be adjusted to accom-
modate larger boxes.
Refer to Specifi cations Section and also
Figure 15266.
7.13 Electrical Connections and Controls
The electrical control box and "On/Off" switch
are located on the lower left side of the machine
frame. See Figure 7-13. If desired, for operator
convenience, the "On/Off" switch can be relocated
to the right side of the machine frame. A standard
three conductor power cord with plug is provided
at the back of the electrical control box for 115 Volt,
60 Hz., 3.8 Amp electrical service. The receptacle
providing this service shall be properly grounded.
Before the power cord is plugged into 115 Volt, 60
Hz outlet make sure that all packaging materials and
tools are removed from the machine.
Do not plug electrical cord into outlet until ready
to run machine.
Use of an extension cord is not recommended.
However, if one is needed for temporary use, it
must have a wire size of 1.5mm diameter [AWG16],
have a maximum length of 30.5 m [100 ft], and
must be properly grounded.
• To reduce the risk associated with
hazardous voltage:
− Position electrical cord away from foot
and/or vehicle traffi c
Note - Machines outside the U.S. may be equipped
with 220/240 Volt, 50 Hz systems, or
other electrical requirements compatible with
local practice.
7.14 Initial Start-Up of Case Sealer
After completing the "Installation and Set-Up"
procedure, continue through "Operation" for tape
loading and start-up to be sure case sealer is
properly adjusted to run boxes
26
WARNING
2010 January