Airwell Wellea Split A R32 Installation Manual page 54

Indoor unit
Hide thumbs Also See for Wellea Split A R32:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
In this case, the setting value of zone 1 is T1S,the setting
value of zone 2 is T1S2.
If you set DOUBLE ZONE and ROOM TEMP. to YES,
meanwhile set WATER FLOW TEMP. to YES or NON,the
following page will be displayed.
Homepage (zone 1)
In this case, the setting value of zone 1 is T1S,the setting
value of zone 2 is T1S2 (The corresponding TIS2 is
calculated according to the climate related curves.)
9.5.6 ROOM THERMOSTAT
About ROOM THERMOSTAT
The ROOM THERMOSTAT is used to set whether the
room thermostat is available.
How to set the ROOM THERMOSTAT
Go
to
MENU>
FOR
SERVICEMAN>
THERMOSTAT. Press OK. The following page will be
displayed:
6 ROOM THERMOSTAT
6.1 ROOM THERMOSTAT
ADJUST
NOTE
ROOM THERMOSTAT = NON, no room thermostat.
ROOM THERMOSTAT = MODE SET, the wiring of
room thermostat should follow method A.
ROOM THERMOSTAT=ONE ZONE, the wiring of
room thermostat should follow method B.
ROOM THERMOSTAT=DOUBLE ZONE, the wiring
of room thermostat should follow method C (refer to
8.8.6 "Connection for other components/For room
thermostat")
2
Addition page (zone 2)
(Double zone is effective)
6.ROOM
NON
53
9.5.7 Other HEATING SOURCE
The OTHER HEATING SOURCE is used to set the
parameters of the backup heater, additional heating
sources and solar energy kit.
Go to MENU> FOR SERVICEMAN> 7.OTHER HEATING
SOURCE, Press OK. The following page will be dispayed:
7 OTHER HEATING SOURCE
7.1 dT1_IBH_ON
7.2 t_IBH_DELAY
7.3 T4_IBH_ON
7.4 dT1_AHS_ON
7.5 t_AHS_DELAY
ADJUST
7 OTHER HEATING SOURCE
7.6 T4_AHS_ON
7.7 IBH LOCATE
7.8 P_IBH1
7.9 P_IBH2
7.10 P_TBH
ADJUST
9.5.8 HOLIDAY AWAY SETTING
The HOLIDAY AWAY SETTING is used to set the outlet
water temperature to prevent freezing when away for
holiday.
Go to MENU> FOR SERVICEMAN> 8.HOLIDAY AWAY
SETTING. Press OK. The following page will be
displayed:
8 HOLIDAY AWAY SETTING
8.1 T1S_H.A._H
8.2 T5S_H.A._DHW
ADJUST
9.5.9 SERVICE CALL SETTING
The installers can set the phone number of the local
dealer in SERVICE CALL SETTING. If the unit doesn't
work properly, call this number for help.
Go to MENU> FOR SERVICEMAN>SERVICE CALL.
Press OK. The following page will be displayed:
9 SERVICE CALL SETTING
PHONE NO. ******************
MOBILE NO. ******************
OK
CONFIRM
ADJUST
Press ▼ ▲ to scroll and set the phone number. The
maximum length of the phone number is 13 digits, if the
length of phone number is short than 12, please input ■,
as shown below:
1/2
5°C
30MIN
-5°C
5°C
30MIN
2/2
-5°C
PIPE LOOP
0.0kW
0.0kW
2.0kW
20°C
20°C

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents