ELECTRO FREEZE Shake Model CS705
13
Troubleshooting Charts
PROBLEM
Unit does not
1.
Freezer unplugged.
operate.
2.
Fuse or breaker blown at main disconnect.
3
Actuator rod not installed.
4.
Off on high pressure cut-out control.
5.
Circuit breaker tripped. .
6.
Faulty selector switch.
7.
Disconnected or broken wire in electrical
circuit.
Mix or water
1.
Damaged beater shaft seal or installed
leaking from
improperly.
drain tube to
drip tray.
Mix leaking at
1.
dispensing
head.
2.
Dispensed
1.
product too soft.
(Product
temperature
2.
above 28°F
[-2.2°C] )
3.
4.
40
PROBABLE CAUSE
Faulty head o-ring.
Head not properly installed.
D irty or blocked condenser, restricted
air flow.
Torque control not set firm enough.
C omponent failure.
Leak in refrigeration system resulting in
little or no refrigeration.
— continued
REMEDY
1.
Plug in freezer.
2.
Make sure your freezer is connected to a
separate circuit independent from any
other electrical equipment. Have
technician check fuse or breaker size and
check for low voltage; if not within 10% of
nameplate rating call power company.
3.
Install actuator rod.
4.
Water turned off or defective water
regulating valve. Check water supply.
5.
Contact your Electro Freeze Distributor
for service
6.
Contact your Electro Freeze Distributor
for service.
7.
Contact your Electro Freeze Distributor
for service.
1.
Replace cup seal. Install properly.
1.
Replace o-ring.
2.
Install head properly. Replace o-ring if
pinched.
1.
Unblock condenser or have cleaned by
your Electro Freeze Distributor.
2.
Contact your Electro Freeze Distributor for
service.
3.
Contact your Electro Freeze Distributor for
service.
4.
Contact your Electro Freeze Distributor for
service.
184592