5 Operator Controls and Indicators
Figure 5-1
The following paragraphs describe the
operator controls and indicators. Refer
to figure 5-1 for location of these
controls and indicators on the freezer.
NOTE: The dispense head must be in
place before the freezer will operate.
5.1
Day– Night Switch
184599
This two-position switch controls the
day and night refrigeration modes.
a. "DAY" (left) — The low tem-
perature thermostat controls the
system refrigeration to maintain the
product serving temperature between
18° to 21ºF (-8° to -6°C). This is the
normal operating position.
ELECTRO FREEZE Soft Serve Model SL500
1
b. "NIGHT" (right) — This energy-
saving mode will reduce product agita-
tion. The freezer will automatically cycle
to maintain temperatures below 40
º
(4
C). Use this position when the freezer
will not be in use for periods of more
than an hour.
CAUTION
Test operation of the head
switch prior to placing the
freezer in service. See
Section 11, Routine
Maintenance, Monthly.