ELECTRO FREEZE Shake Model CS705
2.3

Electrical Connections

3

Specifications

3.1

Particulars

184592
CAUTION
All materials and
connections must conform to
local requirements and be in
compliance with the National
Electric Code (NEC).
CAUTION
To prevent accidental
electrical shock, a receptacle
with a positive earth ground
is required.
1. Always verify electrical specifica-
tions on the data plate (figure 3-2) of each
individual freezer. Data plate specifica-
tions will always supersede the informa-
tion in this manual.
2. This freezer requires a protected
20 amp 230 volt circuit. Connect the
freezer to a circuit separate from any other
electrical equipment. The power cord on
this freezer connects to a NEMA 6-20R
receptacle. See Figure 2-1.
Width (in/cm)
Height (in/cm)
Depth (in/cm)
Weight (lbs/kg)
Voltage*
Min.Circuit Ampacity
Compressor
±10% of voltage indicated on the name-
plate. Request your local power company
to correct any voltage problem.
electrical box is factory wired to 208 volts
(red) wire tap for 208V nominal power
supply. If power supply is between 230-
240 volts use 240V (orange) wire tap on
transformer.
Beater Motor
18.4/46.7
Refrigerant
58.9/149.7
Charge
28.1/71.4
Cooling
250/113.4
Hopper
208-230/60/1
Cylinder
20.0
1 HP/8000 (BTUH)
.75 kw (Motor)
2.3 kw (Cooling)
3. Supply voltage must be within
4. The control transformer in the
Figure 2-1
*Contact factory for other voltages.
1/2 HP/.37 kw
R-404a
32.0 oz/.91 kg
Air
20 qts/18.8 liters
7 qts/7.1 liters
3