NEC Express5800/R320g-M4 Maintenance Manual page 66

Hide thumbs Also See for Express5800/R320g-M4:
Table of Contents

Advertisement

Chapter 1 Maintenance
Messages displayed on a lower LCD line
Message on Lower LCD Line
VBAT Lower Non-Critical
VBAT Upper Non-Critical
VBAT Lower Critical
VBAT Upper Critical
Baseboard Temperature1 Lower Non-Critical
Baseboard Temperature1 Upper Non-Critical
Baseboard Temperature1 Lower Critical
Baseboard Temperature1 Upper Critical
Baseboard Temperature2 Lower Non-Critical
Baseboard Temperature2 Upper Non-Critical
Baseboard Temperature2 Lower Critical
Baseboard Temperature2 Upper Critical
CPU1_DIMM Area Temperature Lower
Non-Critical
CPU1_DIMM Area Temperature Upper
Non-Critical
CPU1_DIMM Area Temperature Lower
Critical
CPU1_DIMM Area Temperature Upper
Critical
CPU2_DIMM Area Temperature Lower
Non-Critical
CPU2_DIMM Area Temperature Upper
Non-Critical
CPU2_DIMM Area Temperature Lower
Critical
CPU2_DIMM Area Temperature Upper
Critical
Processor1 Thermal Control Upper
Non-Critical
Processor1 Thermal Control Upper Critical
Processor2 Thermal Control Upper
Non-Critical
Processor2 Thermal Control Upper Critical
DUMP Request !
Power Supply1 Failure detected
Processor Missing
Processor1 Thermal Trip
Processor2 Thermal Trip
Sensor Failure Detected.
SMI timeout
IPMI Watchdog timer timeout (Power off)
Express5800/R310g-E4, R320g-E4, R320g-M4 Maintenance Guide (Windows)
66
Description
A voltage abnormality was
detected.
A temperature abnormality was
detected.
The dump button was pressed.
A power supply unit abnormality
occurred.
No CPU is installed.
The power was forcibly turned off
due to a CPU temperature
abnormality.
Abnormality in a sensor was
detected.
A timeout occurred while
servicing system management
interrupts.
A watchdog timer timeout
occurred.
6. Error Messages
Action
Contact your sales representative.
It is possible that a cooling fan has
failed or is clogged. Contact your sales
representative.
Wait until collecting the memory dump
data has finished.
Make sure that the power cord is
plugged in.
Contact your sales representative.
Contact your sales representative.
Contact your sales representative.

Hide quick links:

Advertisement

Table of Contents
loading