Chapter 2 Configuring and Upgrading the System
5. Confirm that RDR of the relevant disk is cancelled.
6. Cancel the RDR of disk of the corresponding slot in the same manner.
If the cancelled disk is not displayed properly on Disk Management after the RDR is cancelled, execute the
following:
1. Exit Disk Management.
2. Open Computer Management – Service and execute "Virtual Disk (vds)".
3. Open Disk Management.
If the disk contains a partition which cannot be unmounted such as setting the paging file, the OS needs to be
restarted when canceling RDR. In that case, the system restart pop-up message appears. If you click Close or
OK, the OS is restarted automatically after two minutes:
Express5800/R310g-E4, R320g-E4, R320g-M4 Maintenance Guide (Windows)
128
A partition on the disk where the RDR setting is removed is assigned an arbitrary drive
Tips
letter by the auto mount function of the OS. If you want to reassign the drive letter of the
partition properly, use Disk Management. See Chapter 2 (2. Change Drive Letter).
1. Hard Disk Drive Operations