T1 Physical Configuration - Cabletron Systems WPIM T1 User Manual

Cabletron systems wpim t1/dds user's guide
Table of Contents

Advertisement

The line configuration information shown in
by the service provider.
Configuration Information
Required by User
Line Coding
Frame Type
Clock Source
DS-0s (Timeslots)
3.4.1
T1 Physical Configuration
Begin the WPIM-T1/DDS physical configuration by accessing the WAN
Physical Configuration screen through Local Management
Proceed with the following steps:
1.
Use the arrow keys to highlight the WPIM X field at the bottom of the
screen. Press the SPACE bar to select the number of the WPIM being
configured, then press ENTER.
2.
Use the arrow keys to highlight MgrType. Select PPP.
When changing from one protocol to another on a
NOTE
WPIM-T1/DDS that has been operational, save NONE as the
protocol before changing to another protocol.
3.
Use the arrow keys to highlight Timeslot View. Press the SPACE bar
to select New, then press ENTER. The cursor moves to Timeslot #1 of
the Timeslot Configuration Table.
4.
Insert an interface number (refer to Note below) into every Timeslot
being used (in the example shown back in
used, the rest have zeros in them). Type the number, press ENTER,
then use the arrow keys to highlight the next Timeslot field. Exit this
field by using the arrow keys.The cursor automatically moves to the
T1 Line Coding field.
WPIM-T1/DDS User's Guide
Table 3-2 Telco Configuration Information
Fractional T1 Configuration Using PPP
Table 3-2
Configuration Information
Supplied by Service Provider
B8ZS or AMI
ESF or D4
Loop Timing or Local Timing
Timeslots being used for each end of
the circuit
Figure
must be supplied
(Figure
3-1).
3-7, 16 Timeslots are
3-15