Chapter 2: Setup and Installation
2.4
CONNECTING THE WAN CABLE TO THE
WPIM-T1/DDS
Before connecting any cabling to the WPIM-T1/DDS, the WAN
configuration must be complete. Refer to the previous section for
information
(Section
completed.
DO NOT plug the WAN cable into the external WAN connection
!
until you have properly completed the WAN setup in software. If
CAUTION
this cable is plugged in prematurely, before the host unit is
configured, the telephone company can disable the WAN line
for a period of time. The cable will be plugged in as a final step
once you run the QuickSET configuration, or the Local
Management configuration.
The RJ45 cable from the WPIM-T1/DDS must be plugged into the WAN
connection wall jack (see
with the WPIM-T1/DDS, but may be ordered separately from Cabletron
Systems (cable part number 9372094 for T1, and part number 9360119
for DDS service). Refer to
Figure 2-3 WAN Connection to the WPIM-T1/DDS
2-6
2.3.2) if the WAN configuration has not been
Figure
2-3, below). The cables are not supplied
Appendix A
WAN Connection Wall Jack
for details.
Host Platform
T1
DDS
WPIM
T1/DDS
WPIM-T1/DDS User's Guide