2.
If Frame Relay was selected, use the arrow keys to highlight FR LMI.
Press the SPACE bar to select ANSI_94, NO LMI, T1.617-D, or
Q.933-A, then press ENTER.
If NO LMI was selected, complete the following:
Use the arrow keys to highlight DLCI Address. This field can be
set to values from 0-1023. The values 16-991 are typically used for
virtual circuits.
Use the arrow keys to highlight Circuit State. Press the SPACE
bar to select Active, then press ENTER.
3.
If PPP was selected as the Protocol Manager instead of Frame Relay,
the Max Xmit Unit setting may be changed from the default of 1526 if
desired.
4.
Make any changes to the available settings as desired.
5.
Use the arrow keys to highlight the SAVE command. Press ENTER.
The message "Save Done!" appears and Local Management saves the
changes to memory.
The WAN configuration is complete. Communication between the
WPIM-T1/DDS and the service provider's switch takes approximately
one to two minutes to complete. A status of Inactive displays on a DLCI
per DLCI basis by default until both ends of the DLCI are configured
correctly. Once both end devices have negotiated link management with
the switches, and are configured correctly on a DLCI per DLCI basis, the
status field displays Active.