Chapter 4: Local Management for DDS Service
REMOTE SETUP (Command)
Not used for the WPIM-T1/DDS.
RETURN (Command)
Returns user to the previous screen.
4.1.2
WPIM Line Configuration Fields
The configuration fields displayed on the WAN Physical Configuration
screen shown in
Figure 4-1
are specific to the DDS mode of the
WPIM-T1/DDS.
DDS Line Mode (Toggle)
Displays the DDS Line Mode. The selections toggle between DDS-PRI
(primary) and DDS-CC (clear channel). This field should be set according
to information from the service provider. The default setting for this field
is DDS-PRI.
DDS Tx Clock Source (Toggle)
Displays the clock source as either Loop-Timing or Local-Timing. The
Loop-Timing setting allows the WPIM-T1/DDS to receive its timing
information from the service provider, and the Local-Timing setting
allows the WPIM-T1/DDS to receive its timing information internally. If
DDS-CC is chosen for the DDS Line Mode then this field must be set to
Loop. The default setting is Loop.
DDS Loop-back (Toggle)
Displays the internal Loopback as either Line-Loop or None. Line
loopback is reserved for network diagnostics only. The default is None.
DDS In-Speed (Read-Only)
Displays 56000 (bps) for Primary DDS Line Mode and 64000 (bps) for
Clear Channel DDS Line Mode upon startup.
DDS Out-Speed (Read-Only)
Displays 56000 (bps) for Primary DDS Line Mode and 64000 (bps) for
Clear Channel DDS Line Mode upon startup.