Viessmann Vitotronic 200 Installation And Service Instructions For Contractors page 9

Weather-compensated control unit
Table of Contents

Advertisement

Index
58 Lead break, cylinder temperature sensor 1 ................................... 95
59 Lead break, cylinder temperature sensor 2 ................................... 96
5A Lead break, buffer temperature sensor ......................................... 96
60 Short circuit, temperature sensor 17A ........................................... 96
68 Lead break, temperature sensor 17A ............................................ 96
70 Short circuit, temperature sensor 17B ........................................... 97
78 Lead break, temperature sensor 17B ............................................ 97
90 Short circuit, sensor 7, solar control module, type SM1 ................ 97
91 Short circuit, sensor 10, solar control module, type SM1 .............. 97
92 Short circuit, collector temperature sensor .................................... 97
93 Short circuit, return temperature sensor, collector ......................... 97
94 Short circuit, cylinder temperature sensor, solar ........................... 98
98 Lead break, sensor 7, solar control module, type SM1 ................. 98
99 Lead break, sensor 10, solar control module, type SM1 ............... 98
9A Lead break, collector temperature sensor ..................................... 98
9B Lead break, return temperature sensor, collector ......................... 98
9C Lead break, cylinder temperature sensor, solar ............................ 98
9E Delta T monitoring, solar control unit ............................................ 99
9F Solar control unit ........................................................................... 99
A0 Fault message module 2: Safety equipment 1 .............................. 99
A1 Fault message module 2: Safety equipment 2 .............................. 99
A2 Fault message module 2: Safety equipment 3 .............................. 99
A3 Fault message module 2: Safety equipment 4 .............................. 99
A7 Fault clock module in programming unit ....................................... 100
AA Configuration fault, TSA function .................................................. 100
AB Configuration fault, heat exchanger set ........................................ 100
AC Configuration fault, return temperature control ............................. 100
AD Configuration fault, butterfly valve ................................................ 100
B0 Short circuit, flue gas temperature sensor .................................... 100
B1 Communication fault, programming unit ....................................... 101
B5 EEPROM error .............................................................................. 101
B6 Invalid application ..........................................................................101
B7 Coding card ................................................................................... 101
B8 Flue gas temperature sensor disconnection ................................. 101
BA Communication error, PCB extension, HC 2 and HC 3 ................ 101
BC Communication error, remote control, HC 1 ................................. 102
BD Communication error, remote control, heating circuit 2 ................ 102
BE Communication error, remote control, heating circuit 3 ................ 102
BF Incorrect LON communication module ..........................................102
C1 External safety equipment on boiler ..............................................103
C2 Communication error, solar control unit ........................................ 103
C3 Communication fault, extension AM1 ........................................... 103
C8 Fault message module 1, input 1: Water level limiter ................... 103
C9 Fault message module 1, input 2: Max. pressure 1 ...................... 103
CA Fault message module 1, input 3: Min. pressure or max. pres-
sure 2 ..................................................................................................103
CB Fault message module 1, input 4: Max. pressure 2 ......................104
CE Communication error, fault message module 1 ............................ 104
CF Communication error, LON communication module ..................... 104
D1 Burner fault, boiler .........................................................................104
D2 Communication error, fault message module 2 ............................ 104
D3 Communication error, EA1 extension ........................................... 104
D4 High limit safety cut-out, boiler ...................................................... 105
D6 Fault message at digital input 1, EA1 extension ........................... 105
D7 Fault message at digital input 2, EA1 extension ........................... 105
D8 Fault message at digital input 3, EA1 extension ........................... 105
DA Short circuit, room temperature sensor Vitotrol, HC 1 .................. 105
DB Short circuit, room temperature sensor Vitotrol, HC 2 .................. 105
DC Short circuit, room temperature sensor Vitotrol, HC 3 ..................106
DD Lead break, room temperature sensor Vitotrol, HC 1 ...................106
Index
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Co1e

Table of Contents