Viessmann Vitotronic 200 Installation And Service Instructions For Contractors page 8

Weather-compensated control unit
Table of Contents

Advertisement

Index
Index
7. Diagnosis and service
scans
8. Troubleshooting
8
16 Mixer runtime ................................................................................. 82
17 System dynamics mixer ................................................................. 83
18 Minimum flow temperature limit, heating circuit
19 Maximum flow temperature limit, heating circuit
1B Room influence limit ...................................................................... 83
1F External operating program changeover
20 Extension EA1: Operating program changeover
21 Setting range, set day temperature ............................................... 84
22 Correction, actual room temperature ............................................. 84
23 Screed drying
........................................................................... 84
!
24 Time limit for comfort mode
25 Outside temperature limit for cancelling reduced set room tem-
perature
!
......................................................................................... 86
26 Outside temperature limit for raising the reduced set room tem-
perature to the standard set room temperature
27 Raising the set boiler water or flow temperature when switching
from operation with reduced room temperature to operation with
standard room temperature
28 Duration for raising the set boiler water or flow temperature
Calling up the service menu .................................................................. 87
Exit service ............................................................................................ 88
Change passwords ................................................................................ 88
Resetting all passwords to their factory settings .................................... 88
Diagnosis ............................................................................................... 88
Scanning operating data ..................................................................... 88
Brief scan ............................................................................................ 89
LON service PIN .................................................................................... 90
Calling up WiFi information .................................................................... 90
Reset network module ........................................................................... 90
Enabling service interface for Vitosoft (WiFi) ......................................... 90
Deactivating the WiFi connection ....................................................... 91
Service display ....................................................................................... 91
Acknowledging the service display ..................................................... 91
Calling up acknowledged service messages ...................................... 91
Reset service message ...................................................................... 91
Fault indicator ........................................................................................ 92
Acknowledging the fault display ......................................................... 92
Calling up acknowledged fault messages .......................................... 92
Calling up messages from the message memory .............................. 92
Fault messages ..................................................................................... 92
0F Service .......................................................................................... 92
10 Short circuit, outside temperature sensor ...................................... 92
18 Lead break, outside temperature sensor ....................................... 93
19 Wireless outside temperature sensor ............................................ 93
30 Short circuit, boiler water temperature sensor ............................... 93
38 Lead break, boiler water temperature sensor ................................ 93
3A LAN hardware error ....................................................................... 93
3B LAN system error .......................................................................... 94
3C DHCP server not replying ............................................................. 94
3D Ethernet cable not connected ....................................................... 94
3F Recovery update error ................................................................... 94
40 Short circuit, flow temperature sensor, heating circuit 2 ................ 94
44 Short circuit, flow temperature sensor, heating circuit 3 ................ 94
48 Lead break, flow temperature sensor, heating circuit 2 ................. 94
4C Lead break, flow temperature sensor, heating circuit 3 ................ 95
50 Short circuit, cylinder temperature sensor 1 .................................. 95
51 Short circuit, cylinder temperature sensor 2 .................................. 95
52 Short circuit, buffer temperature sensor ........................................ 95
!
!
.................................. 83
!
!
...................................................... 85
!
............................. 86
!
........................................................... 86
!
....................... 83
...................... 83
...................... 84
.... 86
!