Parameter Setting - Baileigh Industrial SH-120250-HD Operator's Manual

Hydraulic shear
Table of Contents

Advertisement

Parameter Setting

User can setup all parameters required for normal operation of the system, including system
parameter and X axis parameter.
Operation Steps
1. On program management page, press the
as shown in Figure 2-8. On this page, programming constant can be set.
Figure 2-8 Programming constant page
Range of programming constant setup is shown in Table 2-5.
Table 2-5 Range of: programming constant setup
Parameter name
Metric/Inch system
Chinese/English
Version number
Unit
Setup range
-
0 or 1
-
0 or 1
-
-
46
46
button to enter programming constant page,
Default Remarks
1
0: metric, 1: English system
1
0: Chinese, 1: English
Software version information,
V refers to version.
-
1: indicates version number.
0: indicates version level.