PARAMETER GUIDELINES

Clamp Die Pressures

The following table lists the recommended pressures to use when setting up new tooling on the
machine.
Important: Only increase pressure on clamp die if clamp die is slipping over the
material. Stainless steel tubing will always require more pressure than mild steel.
Table 1 Clamp Die Pressure Guidelines
CLAMP DIE PRESSURE GUIDELINES
TUBE OD
3
2.875
2.75
2.625
2.5
2.375
2.25
2.125
2
1.875
1.75
1.625
1.5
1.375
1.25
1.125
1
41
41
PSI
2500
2500
2500
2500
2500
2000
2000
2000
2000
2000
2000
1500
1500
1500
1500
1500
1500