14.2 - Voltage for the AUX output
m
Warning: the Aux output voltage is a division of the
accessory voltage, with a peak value higher than 24V
Default=12VDC
The output voltage of the AUX contact can be set to 12VDC or
24VDC, depending on the connected lock or the available relay.
1. PRESS THE START BUTTON FOR 3 SECONDS: all leds turn
OFF (if not, consult Paragraph 17.1)
2. PRESS THE RADIO BUTTON FOR 1 SECOND
- If the ERROR led is ON
AUX voltage = 12VDC (if the setting is correct, go to Point
5; if not, proceed to Point 3)
- If the ERROR led is OFF
AUX voltage = 24VDC (if the setting is correct, go to Point
5; if not, proceed to Point 4)
3. PRESS THE START BUTTON FOR 1 SECOND: the RADIO
led remains lit and the ERROR led turns OFF. Go to step 5
4. PRESS THE START BUTTON FOR 1 SECOND: the RADIO
led remains lit and the ERROR led turns OFF
5. PRESS THE SET AND RADIO BUTTONS
SIMULTANEOUSLY OR WAIT 10 SECONDS TO EXIT THE
PROCEDURE: the leds return to the normal operation
configuration
14.3 - Programming of the button
linked to the AUX output
This procedure allows for programming the button of the radio
control linked to the AUX output.
To use this function, the AUX output must be set to courtesy light
– see Paragraph 14.2.
1. PRESS THE RADIO BUTTON FOR 1 SECOND: the RADIO
led turns ON
2. PRESS THE SET BUTTON FOR 1 SECOND: the RADIO led
remains lit and the SET led turns ON
3. PRESS THE DESIRED BUTTON OF ALL THE
TRANSMITTERS TO BE PROGRAMMED: the RADIO led
flashes and the SET led remains ON
4. PRESS THE SET AND RADIO BUTTONS
SIMULTANEOUSLY OR WAIT 10 SECONDS TO EXIT THE
PROCEDURE: the RADIO led and the SET led turn OFF
34
Advanced programming (not required for standard installations)
15. Photocells and
safety edges advanced
programming sequences
These programming sequences are not essential to the system's
operation, but they allow for controlling the devices by activating
the photo-test—when photocells are installed—or controlling the
resistance when 8.2kOhm resistive edges are mounted.
m
any time, press the SET and RADIO buttons simultaneously
or wait 10 seconds.
15.1 - Photo-test activation/
deactivation
Default= deactivated
The photo-test is a check aimed at verifying whether the 24VDC-
powegreen photocells function properly.
It consists in cutting off the power supply to the transmitter
photocell (TX) from the control unit, while subsequently verifying
that the contact (PHO1, or PHO1 and PHO2, depending on the
settings in Paragraph 15.2) opens. Subsequently, the control unit
restores the power supply to the transmitter photocell and verifies
that the contact closes.
This occurs before each movement of the automation.
For the test to work, the photocells must be wired
according to the following scheme:
+24V RX photocell = terminal +VA
+24V TX photocell = terminal GSI
m
powered at 24VDC.
m
contacts PHO1 and PHO2. To set this test only on the
contact PHO1, please see paragraph 15.2.
m
status indicator" function (GSI).
m
phototest will only be active on contact PHO1.
1. PRESS THE START BUTTON FOR 3 SECONDS: all leds turn
2. PRESS THE START BUTTON FOR 1 SECOND
3. PRESS THE SET BUTTON FOR 1 SECOND: the START
4. PRESS THE SET BUTTON FOR 1 SECOND: the START led
5. PRESS THE SET AND RADIO BUTTONS
To interrupt the following programming sequences at
The photo-test can only work with photocells
By default the phototest function works on both
By enabling the photocells test, you will lose the "gate
If PHO2 is set as safety edge (DIP 5 OFF) the
OFF (if not, consult Paragraph 17.1)
- If the PHOTO led is ON
photo-test = activated (if the setting is correct, go to Point
5; if not, proceed to Point 3)
- If the PHOTO led is OFF
photo-test = deactivated (if the setting is correct, go to
Point 5; if not, proceed to Point 4)
ledremains ON and the PHOTO led turns OFF. Go to step 5
remains ON and the PHOTO led turns ON
SIMULTANEOUSLY OR WAIT 10 SECONDS TO EXIT THE
PROCEDURE: the leds return to the normal operation
configuration