6. Programming the gate travel
m
Basic (paragraph 6.1) or Advanced (6.3) programming
of the gate travel must be done prior to using the gate.
m
If, at the start of the following procedures, the
SET, RADIO and START LEDs flash, it means that the
programming protection has been activated – see
Paragraph 17.1.
LEAF 1
(gate leaf that opens first,
connected to MOTOR 1)
6.1 - Basic programming of the gate
travel
In this procedure, the control unit will learn the gate travel time
and force to determine a default slowdown point. This procedure
is sufficient for most installations. To cancel or change slowdown
points see paragraph 6.3.
1. MOVE THE GATE TO ABOUT HALF WAY POSITION
2. HOLD THE SET BUTTON FOR APPROX 4 SECONDS: the
SET led will turn ON and the gate will start moving
3. IMMEDIATLY RELEASE THE SET BUTTON: the gate will now
start the setup proceedure
4. THE GATE PERFORMS A PARTIAL OPENING MOVEMENT
(*): the SET led stays ON
5. THE GATE PERFORMS A FULL CLOSING MOVEMENT:
the SET led stays ON
6. THE GATE PERFORMS A FULL OPENING MOVEMENT:
the SET led stays ON
7. THE GATE PERFORMS A FULL CLOSING MOVEMENT:
the SET led turns OFF
8. END OF THE PROGRAMMING PROCEDURE: the leds return
to the normal operation configuration
m
(*) CAUTION! - if the automation starts a closing
stroke instead of an opening stroke, proceed as follows:
1. quit programming by pressing SET and RADIO
simultaneously:
For SWING GATE MOTORS: swap the motor phases
(terminals MOT1, MOT2).
For SLIDING GATE MOTORS: change the setting of DIP8,
see par. 4.1. Alternatively, swap the motor phases (terminals
MOT1, MOT2) and the inputs of any limit switches (terminals
OL1, CL1, GND, OL2, CL2).
2. reprogram the stroke from point 1.
m
To interrupt the following programming sequences
at any time, press the SET and RADIO buttons
simultaneously.
(gate leaf that opens second,
connected to MOTOR 2)
m
If the operator does not recognise the mechanical
stops (end of the travel for swing gates) even with the
OBS knob set to its minimum, you can select the open and
closed points during programming by pressing the SET
button (or a programmed transmitter's button) at the end of
points 5, 6 and 7.
In the event of two gate leaves, use the SET button for both
leaves.
m
The red ERROR LED flashes during travel and at the
end of travel points. This occurs when the motor is using
high current.
It is normal for the error light to flash briefly during travel.
If the error light up longer than brief interval then increase
the obstacle knob and check again. ( make sure you have
enough force with the obstacle adjustment so the gate will
not stop in case of wind).
m
After any POWER knob adjustment, the gate travel
learning must be reprogrammed.