King gates STARG8 24NG Installation And Use Instructions Manual page 25

Control unit for 24v sliding and swing gates motors
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 21
PHOTOCELLS / SAFETY EDGES
TX
MOT 2
MOT 1
PH 01
PH 02
GND
+ VA
GS I
OL 1
CL 1
GND
OL 2
CL 2
STR
GND
STP
PED
GND
ANT
1 2 3 4 5 6 7 8
Note: For devices connected to
PHO1, PHO2 or STOP
1) Inputs must be dry contacts
(voltage-free), and the relevant
factory bridge must be removed.
2) Multiple devices connected to a
single input must be connected in
series.
FLASHING LIGHT,
ELECTRIC LOCK,
WIRED COMMANDS
MOT 2
MOT 1
PH 01
PH 02
GND
+ VA
GS I
OL 1
CL 1
GND
OL 2
CL 2
STR
GND
STP
PED
GND
ANT
1 2 3 4 5 6 7 8
RX
2
PH1
m
Devices connected to PH01 are
tipically installed outside the gate. Devices
connected to PH02 are tipically installed
inside the gate (see the alongside scheme).
2
1
Note: Any devices connected to START or PED inputs must be dry contacts (voltage
free).
Multiple devices connected to a single input must be connected in series.
TX
RX
NC
1 2
1 2 3 4 5
Devices connected to PH01 terminal are
active just in closing phase. Connect
photocells to PH02 to activate it in opening
and closing phases as per DIP5 setup.
OUT
PH1
IN
PH2
TX
RX
3
PH2
1 2
1 2 3 4 5
OUT
PH1
PH2
IN
NC
23