Key:
X!
= Device part number
X@
= Firmware version
X#
= IP address
X$
= Subnet mask
X%
= Gateway IP
X^
= MAC address
X&
= Dante device name
X*
= Executive mode status
X(
= Preset number
X1#
= Detailed firmware information
X1$
= Verbose mode
X1%
= DHCP status
X1^
= Device status

DSP SIS Commands

Parameters such as gain, mute, and phantom power can be set using SIS commands. DSP
SIS commands adhere to the following structure:
E
In this structure, <Parameter ID> defines which parameter is being set (gain, mute,
phantom power), <OID> (Object ID) defines which input or output is being affected, and
<Value> defines the gain, attenuation, mute, or phantom power status with a numerical
value. See the example command below:
E
This command sets the G paramter (gain) of OID 40000 (mic/line input 1) to a value of
12 (+12 dB).
For a complete list of mic/line input and output OID numbers and acceptable gain value
ranges for each input and output, see
on the next page.
<Parameter ID><OID>*<Value>AU
}
G40000*12AU
AXI 22 AT = 60-1627-01, AXI 44 AT = 60-1628-01
n.nn or n.nn.nnnn (major.minor.patch)
xxx.xxx.xxx.xxx
xxx.xxx.xxx.xxx
xxx.xxx.xxx.xxx
xx-xx-xx-xx-xx-xx
Device names follow Domain Name System (DNS)
hostname rules. Legal characters are A-Z, a-z, 0-9,
and hyphen (-). Names must begin with a letter and
cannot end with a hyphen (-).
2 = locked (view only), 1 = locked, 0 = unlocked
1-8
<bootloader version>-<factory code version>
-<updated code version>
0 = Clear/none
1 = Verbose mode (default for USB)
2 = Tagged responses for queries
3 = Verbose mode and tagged responses for queries
1 = enabled (default), 0 = disabled
POWERUP = Device is powering up
POWERDOWN = Device is powering down
READY = Device is ready
BUSY = Device is busy
COMM_ERROR = Communication error
FIRMWARE_UPGRADING = Firmware is upgrading
REBOOT_REQUIRED = Dante device reboot is required
REBOOTING = Dante device is rebooting
}
Object ID (OID) Number and Value Range Tables