The length of the exposed wires in the stripping process is critical. The ideal
length is 3/16 inches (5 mm). If the wires are any longer, the exposed wires
may touch, causing a short circuit between them. If they are any shorter, the
wires can be easily pulled out even if tightly fastened by the captive screws.
La longueur des câbles exposés est primordiale lorsque l'on entreprend de
les dénuder. La longueur idéale est de 5 mm (3/16 inches). S'ils sont un peu
plus longs, les câbles exposés pourraient se toucher et provoquer un court
circuit. S'ils sont un peu plus courts, ils pourraient sortir, même s'ils sont
attachés par les vis captives.
NOTE: Do not tin the wires. Tinned wire does not hold its shape and can become
loose over time.
Mic/Line Inputs — Connect two mono balanced or unbalanced microphone or line
B
level sources (AXI 22 AT) or four mono balanced or unbalanced microphone or line level
sources (AXI 44 AT) using 6-pole 3.5 mm captive screw input connectors (see 3-pole
Audio Input Wiring in figure 5). Phantom power is available on all inputs.
Instead of two or four mono sources, one balanced or unbalanced stereo signal
(AXI 22 AT) or two balanced or unbalanced stereo sources (AXI 44 AT) can be
connected using 6-pole captive screw connectors (see 6-pole Audio Input Wiring in
figure 5).
3
" (5 mm) MAX. (typ)
16
Tip
Ring
Sleeve
Balanced Input
3-pole Audio INPUT Wiring
Figure 5.
3-pole and 6-pole Audio Input Wiring
Line Outputs — Connect two mono balanced or unbalanced line level devices
C
(AXI 22 AT) or four mono balanced or unbalanced line level devices (AXI 44 AT) using
6-pole 3.5 mm captive screw connectors (see 3-pole Audio Output Wiring in figure 6).
Instead of two or four mono line level devices, one stereo device (AXI 22 AT) or two
stereo devices (AXI 44 AT) can be connected using 6-pole captive screw connectors
(see 6-pole Audio Output Wiring in figure 6).
Tip
NO Ground Here
Ring
Sleeve
Tip
NO Ground Here
Ring
Sleeve
Balanced Output
6-pole Audio OUTPUT Wiring
Figure 6.
6-pole and 3-pole Audio Output Wiring
AT (PoE) Port — Connect an Ethernet cable to this RJ-45 port to connect the
D
AXI 22 AT or AXI 44 AT to a Dante network. This connector supports digital audio
transport (AT), communication with the Dante network, and power over Ethernet (PoE).
Tip
Ring
Sleeve
Tip
Tip
Ring
Sleeve
Sleeve
Jumper
Unbalanced Input
Tip
Sleeve
Tip
Tip
Ring
Sleeve
Sleeve
Balanced Output
Unbalanced Output
AXI 22 AT and AXI 44 AT • Installation and Operation
Tip
Sleeve
Jumper
Tip
Sleeve
Jumper
Balanced Input
Unbalanced Input
6-pole Audio INPUT Wiring
Tip
NO Ground Here
Sleeve
Unbalanced Output
3-pole Audio OUTPUT Wiring